INQUIRE NOW
Products Name: HIMA F3 DIO 16/8 01 Programmable controller
PRODUCT DESCRIPTION
HIMA Digital Output Modules Overview
HIMA digital output modules are essential components of HIMA safety control systems, used to output safety-related control signals to field actuators such as valves, relays, and contactors. These modules are designed for high reliability and safety to meet the demands of safety-critical industrial applications.
Product Detailed Description
Function:
Receives safety-related control signals from the HIMA safety controller.
Converts these signals into electrical signals suitable for driving field actuators.
Provides channel-level diagnostics to detect faults in the output circuits (e.g., short circuit, open circuit, external power supply failure).
Some modules feature current limiting or overload protection.
Supports hot-swapping for easy maintenance and replacement.
Features:
High reliability, suitable for SIL (Safety Integrity Level) 2 or SIL 3 applications (depending on the specific model and system configuration).
Force-guided contacts (in some models) ensure safe shutdown.
Channel-level fail-safe design; outputs enter a safe state upon fault detection.
Variety of output types (e.g., relay output, transistor output, solid-state relay output) to accommodate different actuators.
Wide range of voltage and current specifications.
Robust industrial design to withstand harsh environments.
Product Parameters
As HIMA offers a wide variety of digital output modules, the following are some general parameters. Always refer to the official datasheet for the specific model:
Number of Output Channels:
E.g., 8 channels, 16 channels, 32 channels.
Output Type:
Relay.
Transistor (PNP/NPN).
Solid State Relay (SSR).
Rated Output Voltage:
E.g., 24 V DC, 48 V DC, 115 V AC, 230 V AC.
Rated Output Current:
E.g., 2 A, 5 A (depending on the channel and module).
Diagnostic Functions:
Short circuit detection.
Open circuit detection.
External power supply monitoring.
Wire break detection (some models).
Isolation Voltage:
Input/output isolation, channel-to-channel isolation (depending on the model).
Degree of Protection (IP):
E.g., IP20.
Ambient Temperature:
Operating temperature range typically from -25 °C to +60 °C (depending on the model).
Standards Compliance:
IEC 61508 (SIL 2/SIL 3).
EN 61131-2.
Product Advantages
High Safety:
Specifically designed for safety-critical applications, meeting SIL level requirements.
Force-guided contacts and fail-safe design ensure system safety.
High Reliability:
Robust industrial design and strict quality control.
Channel-level diagnostics improve system availability.
Flexibility:
Wide range of output types, voltage, and current specifications to accommodate different actuators.
Hot-swapping capability for easy maintenance.
Easy Integration:
Seamless integration with HIMA safety controllers.
Comprehensive Diagnostics:
Quickly identify and locate faults, reducing downtime.
Precautions
Correct Selection:
Choose the appropriate digital output module based on the type, voltage, current requirements of the actuators, and safety integrity level requirements.
Correct Installation:
Follow HIMA's installation guidelines, ensuring the module is securely mounted and correctly connected.
Correct Wiring:
Connect the module and field actuators correctly according to the wiring diagram, ensuring correct polarity.
Power Requirements:
Use a power supply that meets the specifications and ensure it is stable and reliable.
Safety Circuit Design:
Integrate the digital output module into a safety circuit that complies with relevant safety standards.
Regular Inspection and Testing:
Regularly check the module's operating status and connections, and perform functional tests to ensure proper operation.
Environmental Conditions:
Ensure the operating environment temperature and humidity are within the permissible range.
Product Applications
HIMA digital output modules are widely used in various safety-critical industrial sectors, including but not limited to:
Process Industry:
Safety Instrumented Systems (SIS).
Emergency Shutdown Systems (ESD).
Fire and Gas Detection Systems (F&G).
High Integrity Pressure Protection Systems (HIPPS).
Rail Transportation:
Signaling systems.
Door control systems.
Braking systems.
Energy Industry:
Safety systems for power plants.
Safety control for oil and gas platforms.
Other Safety-Critical Applications:
Any industrial field requiring high reliability and safety.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
HIMA | Z7134/3334/C5/P2 | HIMA | F3105 (17.047) |
HIMA | Z7134/3334/C5/P2 | HIMA | F3108 17039 |
HIMA | 933236300-5 | HIMA | F3113 (17.033) |
HIMA | 933237100-5 | HIMA | F3113a (17.048) |
HIMA | 936217800-5 | HIMA | F3209 17012 |
HIMA | 936217900-5 | HIMA | F3211A (17.061) |
HIMA | 936217900-5 | HIMA | F3212A |
HIMA | 98-4862702 | HIMA | F3213A |
HIMA | 98-4862702 | HIMA | F3213A |
HIMA | BRH2106 | HIMA | F3215A |
HIMA | BV7044-15 | HIMA | F3226(17.007) |
HIMA | BV7044-30 | HIMA | F3316 (17.031) |
HIMA | F1101 | HIMA | F3328 (17.008) |
HIMA | F1107 17001 | HIMA | F3330 17013 |
HIMA | F1201 (17.040) | HIMA | F3334 |
HIMA | F1202 (17.046) | HIMA | F3403 (17.038) |
HIMA | F2101 (17.025) | HIMA | F3406a (17.049) |
HIMA | F2102 (17.045) | HIMA | F3410 (17.062) |
HIMA | F2103a (17.050) | HIMA | F3417A |
HIMA | F2108 (17.019) | HIMA | F3417a (17.034) |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020