PRODUCT DESCRIPTION

ABB GIR5252100R3261 07KT94B Overview

Based on the search results, the ABB GIR5252100R3261 07KT94B is a component or module of a Gas-Insulated Switchgear (GIS). Specifically, it appears to be related to a Circuit Breaker. The designation "07KT94B" might be a specific configuration code or serial number.

As a critical component of a gas-insulated switchgear, its detailed information is typically very technical and may require reference to ABB's professional documentation. The following description is based on a general understanding of GIS circuit breakers and some clues from the search results.

Product Detailed Description

  • Function:

    • As a key component in gas-insulated switchgear, the primary function of the GIR5252100R3261 07KT94B circuit breaker is to safely interrupt and connect high-voltage circuits in power systems.

    • It can perform switching operations under normal operating conditions and quickly interrupt current during faults (such as short circuits) to protect equipment and the system.

    • Gas insulation (typically SF6) is used as both the insulating and arc-quenching medium, offering excellent electrical performance.

  • Features:

    • Gas Insulation (SF6): Utilizes sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium, providing high dielectric strength and reliable arc-quenching capability.

    • Modular Design: As part of a GIS, it typically features a modular design for easy installation, expansion, and maintenance.

    • High Reliability: Specifically designed for high-voltage applications with high reliability and a long service life.

    • Compact Structure: Gas insulation technology allows for a compact equipment structure, reducing space requirements.

    • Integration: Often integrated with other GIS components (such as disconnectors, earthing switches, current transformers, voltage transformers, etc.) within a single enclosure.

Product Parameters

Since the specific model's parameters are very detailed and critical, the following provides a general range of GIS circuit breaker parameters. Always refer to the official technical documentation for the ABB GIR5252100R3261 07KT94B:

  • Rated Voltage: May range from tens of kilovolts to hundreds of kilovolts (e.g., 110 kV, 220 kV).

  • Rated Current: May range from hundreds of amperes to thousands of amperes (e.g., 1200 A, 2500 A).

  • Rated Short-Circuit Breaking Current: May range from tens of kiloamperes to hundreds of kiloamperes (e.g., 40 kA, 63 kA).

  • Rated Short-Circuit Withstand Current: Typically related to the rated short-circuit breaking current.

  • Rated Peak Withstand Current: Typically several times the rated short-circuit breaking current.

  • Operating Mechanism: May employ spring mechanisms, hydraulic mechanisms, etc.

  • Insulating Gas: SF6 (Sulfur Hexafluoride).

  • Protection Degree: GIS equipment typically has a high protection degree (e.g., IP65).

  • Ambient Temperature: Operating temperature range is usually around -25 °C to +40 °C.

  • Mechanical Endurance: May range from thousands to tens of thousands of operations.

  • Electrical Endurance: Depends on the magnitude of the interrupted current.

Product Advantages

  • High Reliability: Gas insulation provides stable electrical performance, reducing the risk of failures.

  • High Safety: Fully enclosed structure reduces the risk of electric shock.

  • Low Maintenance: The gas-insulated environment reduces component corrosion and contamination, lowering maintenance requirements.

  • Small Footprint: Compact design saves substation space.

  • Environmentally Friendly (Modern Design Trends): Although SF6 is a potent greenhouse gas, modern GIS equipment emphasizes gas sealing and leakage control, and actively develops alternative gas solutions.

  • Excellent Arc-Quenching Performance: SF6 gas has a fast and effective arc-quenching capability, reliably interrupting fault currents.

Precautions

  • Strictly follow ABB's technical specifications for installation, operation, and maintenance.

  • Operation and maintenance should be performed by qualified electrical engineers.

  • Regularly check the pressure and leakage of SF6 gas to ensure it is within the safe range.

  • The operating mechanism requires regular inspection and lubrication.

  • Before performing any maintenance work, always completely disconnect the power supply and ground the equipment.

  • Pay attention to environmental protection and handle SF6 gas according to regulations.

Product Applications

As a key component of gas-insulated switchgear, the ABB GIR5252100R3261 07KT94B circuit breaker is mainly used in high-voltage and extra-high-voltage power systems, such as:

  • Substations: For controlling and protecting transformers, busbars, lines, etc.

  • Power Plants: For connecting and protecting generator units.

  • Transmission Lines: For switching and protecting lines.

  • Industrial Sector: For power distribution and protection for large industrial users.

  • Urban Power Grids: Particularly suitable for space-constrained urban environments.

ABB GIR5252100R3261 07KT94B

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

ABBIMDSO14ABBPM856ABBTU836
ABBIMDSI02ABBPM860ABBTU837
ABBNLIS01ABBPM861ABBTU838
ABBNCIS02ABBPM864ABBTU842
ABBNIMF02ABBPM861AABBTU843
ABBNSDO04ABBPM856KO1ABBTU844
ABBIMCIS02ABBPM851K01ABBTU845
ABBNDSI02ABBPM860KO1ABBTU890
ABBIMCIS-02ABBPM861AKO1ABBTU891
ABBNTMP-01ABBCI860ABBTY801
ABBNDSM05ABBCI853ABBTY804
ABBIMDSI-13ABBCI855ABBDI840
ABBNASM03ABBCI857ABBDI845
ABBNMFC02ABBCI858ABBDI890
ABBNRIO-02ABBSD821ABBDP820
ABBIMSPM01ABBSD822ABBDP840
ABBIMMFC04ABBSD823ABBDI81O
ABB57160001-UHABBSS822ABBDI811
ABBIMDSM-04ABBCI801ABBDI814
ABBNASI-02ABBCI840ABBDI820
ABBIMDSO-04ABBTU846ABBDI821
ABBNCTM-01ABBTU847ABBDI830
ABBNCIS-01ABBTB847ABBDI831
ABBNSBM01ABBTB820ABBDO810
ABBNSIM-01ABBTB840ABBDO814
ABB57160001-AABBTU840ABBDO815
ABBNTAI02ABBTU841ABBDO821
ABBIMFBS01ABBTU81OABBDO890
ABB57310001-KHABBTU811ABBAI810
ABB57120001-HPABBTU812ABBAI820

E-mail: alex@fenoux.com

Tel.: +86 13338369201

Skype: +86  13338369201

WhatsApp: +86  13338369201