Brand: ABB
Model number:GIR5252100R3261 07KT94B
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.2kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
ABB GIR5252100R3261 07KT94B Three-phase AC contactor
INQUIRE NOW
Products Name: ABB GIR5252100R3261 07KT94B Three-phase AC contactor
PRODUCT DESCRIPTION
ABB GIR5252100R3261 07KT94B Overview
Based on the search results, the ABB GIR5252100R3261 07KT94B is a component or module of a Gas-Insulated Switchgear (GIS). Specifically, it appears to be related to a Circuit Breaker. The designation "07KT94B" might be a specific configuration code or serial number.
As a critical component of a gas-insulated switchgear, its detailed information is typically very technical and may require reference to ABB's professional documentation. The following description is based on a general understanding of GIS circuit breakers and some clues from the search results.
Product Detailed Description
Function:
As a key component in gas-insulated switchgear, the primary function of the GIR5252100R3261 07KT94B circuit breaker is to safely interrupt and connect high-voltage circuits in power systems.
It can perform switching operations under normal operating conditions and quickly interrupt current during faults (such as short circuits) to protect equipment and the system.
Gas insulation (typically SF6) is used as both the insulating and arc-quenching medium, offering excellent electrical performance.
Features:
Gas Insulation (SF6): Utilizes sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium, providing high dielectric strength and reliable arc-quenching capability.
Modular Design: As part of a GIS, it typically features a modular design for easy installation, expansion, and maintenance.
High Reliability: Specifically designed for high-voltage applications with high reliability and a long service life.
Compact Structure: Gas insulation technology allows for a compact equipment structure, reducing space requirements.
Integration: Often integrated with other GIS components (such as disconnectors, earthing switches, current transformers, voltage transformers, etc.) within a single enclosure.
Product Parameters
Since the specific model's parameters are very detailed and critical, the following provides a general range of GIS circuit breaker parameters. Always refer to the official technical documentation for the ABB GIR5252100R3261 07KT94B:
Rated Voltage: May range from tens of kilovolts to hundreds of kilovolts (e.g., 110 kV, 220 kV).
Rated Current: May range from hundreds of amperes to thousands of amperes (e.g., 1200 A, 2500 A).
Rated Short-Circuit Breaking Current: May range from tens of kiloamperes to hundreds of kiloamperes (e.g., 40 kA, 63 kA).
Rated Short-Circuit Withstand Current: Typically related to the rated short-circuit breaking current.
Rated Peak Withstand Current: Typically several times the rated short-circuit breaking current.
Operating Mechanism: May employ spring mechanisms, hydraulic mechanisms, etc.
Insulating Gas: SF6 (Sulfur Hexafluoride).
Protection Degree: GIS equipment typically has a high protection degree (e.g., IP65).
Ambient Temperature: Operating temperature range is usually around -25 °C to +40 °C.
Mechanical Endurance: May range from thousands to tens of thousands of operations.
Electrical Endurance: Depends on the magnitude of the interrupted current.
Product Advantages
High Reliability: Gas insulation provides stable electrical performance, reducing the risk of failures.
High Safety: Fully enclosed structure reduces the risk of electric shock.
Low Maintenance: The gas-insulated environment reduces component corrosion and contamination, lowering maintenance requirements.
Small Footprint: Compact design saves substation space.
Environmentally Friendly (Modern Design Trends): Although SF6 is a potent greenhouse gas, modern GIS equipment emphasizes gas sealing and leakage control, and actively develops alternative gas solutions.
Excellent Arc-Quenching Performance: SF6 gas has a fast and effective arc-quenching capability, reliably interrupting fault currents.
Precautions
Strictly follow ABB's technical specifications for installation, operation, and maintenance.
Operation and maintenance should be performed by qualified electrical engineers.
Regularly check the pressure and leakage of SF6 gas to ensure it is within the safe range.
The operating mechanism requires regular inspection and lubrication.
Before performing any maintenance work, always completely disconnect the power supply and ground the equipment.
Pay attention to environmental protection and handle SF6 gas according to regulations.
Product Applications
As a key component of gas-insulated switchgear, the ABB GIR5252100R3261 07KT94B circuit breaker is mainly used in high-voltage and extra-high-voltage power systems, such as:
Substations: For controlling and protecting transformers, busbars, lines, etc.
Power Plants: For connecting and protecting generator units.
Transmission Lines: For switching and protecting lines.
Industrial Sector: For power distribution and protection for large industrial users.
Urban Power Grids: Particularly suitable for space-constrained urban environments.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
ABB | IMDSO14 | ABB | PM856 | ABB | TU836 |
ABB | IMDSI02 | ABB | PM860 | ABB | TU837 |
ABB | NLIS01 | ABB | PM861 | ABB | TU838 |
ABB | NCIS02 | ABB | PM864 | ABB | TU842 |
ABB | NIMF02 | ABB | PM861A | ABB | TU843 |
ABB | NSDO04 | ABB | PM856KO1 | ABB | TU844 |
ABB | IMCIS02 | ABB | PM851K01 | ABB | TU845 |
ABB | NDSI02 | ABB | PM860KO1 | ABB | TU890 |
ABB | IMCIS-02 | ABB | PM861AKO1 | ABB | TU891 |
ABB | NTMP-01 | ABB | CI860 | ABB | TY801 |
ABB | NDSM05 | ABB | CI853 | ABB | TY804 |
ABB | IMDSI-13 | ABB | CI855 | ABB | DI840 |
ABB | NASM03 | ABB | CI857 | ABB | DI845 |
ABB | NMFC02 | ABB | CI858 | ABB | DI890 |
ABB | NRIO-02 | ABB | SD821 | ABB | DP820 |
ABB | IMSPM01 | ABB | SD822 | ABB | DP840 |
ABB | IMMFC04 | ABB | SD823 | ABB | DI81O |
ABB | 57160001-UH | ABB | SS822 | ABB | DI811 |
ABB | IMDSM-04 | ABB | CI801 | ABB | DI814 |
ABB | NASI-02 | ABB | CI840 | ABB | DI820 |
ABB | IMDSO-04 | ABB | TU846 | ABB | DI821 |
ABB | NCTM-01 | ABB | TU847 | ABB | DI830 |
ABB | NCIS-01 | ABB | TB847 | ABB | DI831 |
ABB | NSBM01 | ABB | TB820 | ABB | DO810 |
ABB | NSIM-01 | ABB | TB840 | ABB | DO814 |
ABB | 57160001-A | ABB | TU840 | ABB | DO815 |
ABB | NTAI02 | ABB | TU841 | ABB | DO821 |
ABB | IMFBS01 | ABB | TU81O | ABB | DO890 |
ABB | 57310001-KH | ABB | TU811 | ABB | AI810 |
ABB | 57120001-HP | ABB | TU812 | ABB | AI820 |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020