Brand:AB
Model number:1734-IE4С
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.225kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
A-B 1734-IE4С REV H Digital Qutput Termination
INQUIRE NOW
Products Name: A-B 1734-IE4С REV H Digital Qutput Termination
PRODUCT DESCRIPTION
Product Detailed Description
Core Function: The EtherNet/IP adapter acts as a communication bridge between the high-speed EtherNet/IP industrial network and the modular POINT I/O backplane. It aggregates the I/O data from all connected POINT I/O modules (digital, analog, specialty, safety) and exchanges this data with the controller over EtherNet/IP.
Modular System: POINT I/O is a highly modular and compact I/O platform. The adapter connects to a power supply module and then to a series of I/O modules (up to 8, 16, or more depending on the adapter type and power requirements) that snap onto a common backplane.
Communication Protocol: Utilizes EtherNet/IP, an open industrial Ethernet network that uses standard Ethernet technology (IEEE 802.3 and TCP/IP suite) with the Common Industrial Protocol (CIP) for I/O, messaging, and configuration. This provides high-speed, deterministic, and flexible communication.
Network Features:
Dual Ethernet Ports (DLR): Many modern POINT I/O EtherNet/IP adapters feature two Ethernet ports, supporting Device Level Ring (DLR) topology for network redundancy, enhancing system uptime.
CIP Sync: Supports CIP Sync for precise time synchronization across the network, crucial for coordinated motion and high-speed applications.
Built-in Web Server: Some adapters include an embedded web server for basic configuration, diagnostics, and monitoring via a standard web browser.
Diagnostic Capabilities: Provides extensive diagnostic information about the adapter itself, the power supply, and each connected I/O module, facilitating troubleshooting.
Configuration: Typically configured using Rockwell Software Studio 5000 Logix Designer (for Logix controllers) or Rockwell Software RSLinx Classic/Enterprise.
Product Parameters
(Note: Specific part numbers for POINT I/O EtherNet/IP adapters include models like 1734-AENT, 1734-AENTR. The parameters below are general for these types of adapters, and you should always refer to the specific datasheet for the exact model.)
Network Protocol: EtherNet/IP (CIP)
Number of Ethernet Ports: 1 or 2 (for DLR capability)
Ethernet Connection: RJ45
Data Rate: 10/100 Mbps (auto-negotiation)
Power Supply (for adapter itself): Typically 24V DC nominal (range: 10-28V DC or 10-30V DC depending on model)
Current Draw: Varies by model, typically 100-300 mA (adapter only, excluding I/O modules)
Max Number of I/O Modules: Typically up to 8, 16, or more I/O modules per adapter (varies by adapter model and backplane current capability).
Backplane Current: Limited by the adapter and power supply module (e.g., 1000mA or 1500mA for I/O modules).
Module Capacity: Up to 256 digital points or 128 analog channels per adapter (depending on module types).
Status Indicators: LEDs for network status (LINK, ACT), module status (MODULE STATUS), power (PWR), and fault (FAULT).
Operating Temperature: Typically 0 °C to 60 °C (32 °F to 140 °F)
Storage Temperature: Typically -40 °C to 85 °C (-40 °F to 185 °F)
Humidity: 5-95% non-condensing
Mounting: DIN rail mountable
Certifications: UL, c-UL, CE, RCM, ATEX/IECEx (for hazardous locations, depending on specific model and configuration).
Product Advantages
Modularity and Flexibility: POINT I/O's modular design allows users to select only the I/O types and densities needed for a specific application, providing flexibility and cost savings.
Compact Footprint: The small size of POINT I/O modules saves valuable panel space compared to larger I/O platforms.
Distributed I/O: Enables I/O to be placed close to sensors and actuators, significantly reducing wiring costs, installation time, and potential for noise interference.
EtherNet/IP Integration: Seamless integration with Rockwell Automation's Logix controllers and other EtherNet/IP compatible devices, leveraging the benefits of a widely adopted open industrial Ethernet standard.
Network Redundancy (DLR): Adapters with dual ports support DLR, providing enhanced network uptime and fault tolerance, critical for continuous operations.
Scalability: Easily expand I/O capacity by adding more modules to the adapter or additional adapters to the network.
Advanced Diagnostics: Comprehensive diagnostics reduce troubleshooting time and improve system uptime.
Hot Swappable: Many POINT I/O modules can be hot-swapped without removing power from the adapter, facilitating maintenance and reducing downtime.
Precautions
Proper Power Sizing: Ensure the selected power supply module (e.g., 1734-PS) can provide sufficient current for all connected I/O modules and the adapter itself. Exceeding the backplane current limit can lead to unpredictable behavior.
Network Design: Adhere to EtherNet/IP network design best practices, including proper cabling (shielded Ethernet cables for industrial environments), cable lengths, and network topology.
IP Address Configuration: Correctly configure the IP address of the EtherNet/IP adapter using BOOTP/DHCP or manually. Incorrect IP addressing is a common source of communication issues.
Studio 5000 Configuration: Ensure the adapter and all connected I/O modules are correctly configured in Studio 5000 Logix Designer (or equivalent software) to match the physical hardware.
Environmental Conditions: Install the adapter within its specified operating temperature and humidity ranges. Avoid areas with excessive vibration, corrosive atmospheres, or direct exposure to liquids unless using appropriately rated enclosures.
Grounding: Proper grounding of the adapter and the overall control system is crucial for signal integrity and noise immunity.
Firmware Compatibility: Ensure the firmware version of the adapter is compatible with the controller and the version of Studio 5000 Logix Designer being used.
Safety Considerations: For safety applications, ensure that safety-rated POINT I/O modules and safety controllers are used in accordance with relevant safety standards (e.g., ISO 13849, IEC 62061). The standard EtherNet/IP adapter (e.g., 1734-AENT) is not safety-rated for direct connection to safety I/O; a dedicated safety adapter (e.g., 1734-AENTR for GuardLogix) is required for safety over EtherNet/IP (CIP Safety).
Product Applications
The A-B POINT I/O EtherNet/IP Adapter and the POINT I/O system are widely applied across various industrial sectors due to their versatility and compact nature:
Discrete Manufacturing:
Assembly lines
Packaging machinery
Material handling systems (conveyors, robotics)
Machine control
Process Control:
Smaller-scale process control applications
Distributed control elements in larger systems
Water/wastewater treatment
Food and Beverage processing
Building Automation:
HVAC control
Lighting control
Access control systems
Automotive Industry:
Body shop control
Powertrain assembly
Energy and Utilities:
Small-scale power generation monitoring
Oil and gas field instrumentation (with appropriate hazardous area certifications)
Pharmaceutical and Life Sciences:
Skid-mounted systems
Cleanroom applications (within suitable enclosures)
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapor
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products
Allen-Bradley | 1756-L1 | Allen-Bradley | 1454-9F | Allen-Bradley | 1770-FF |
Allen-Bradley | 1756-L55 | Allen-Bradley | 1746-IV32 | Allen-Bradley | 1770-XYC |
Allen-Bradley | 1756-L62S | Allen-Bradley | 1746-OA8 | Allen-Bradley | 1771-ASB |
Allen-Bradley | 1756-M14 | Allen-Bradley | 1746-OX8 | Allen-Bradley | 1771-IAD |
Allen-Bradley | 1756-N2 | Allen-Bradley | 1746-P1 | Allen-Bradley | 1771-IR |
Allen-Bradley | 1756-OB16D | Allen-Bradley | 1746-P2 | Allen-Bradley | 1771-IVN |
Allen-Bradley | 1756-OF4 | Allen-Bradley | 1746-P4 | Allen-Bradley | 1771-IXHR |
Allen-Bradley | 1756-OF8 | Allen-Bradley | 1747-BA | Allen-Bradley | 1771-NC6 |
Allen-Bradley | 1756-PB72 | Allen-Bradley | 1747-DCM | Allen-Bradley | 1771-OFE2 |
Allen-Bradley | 1756-TBCH | Allen-Bradley | 1747-FC | Allen-Bradley | 1771-OZ |
Allen-Bradley | 1756-TBNH | Allen-Bradley | 1747-M11 | Allen-Bradley | 1771-OZL |
Allen-Bradley | 1756-TBS6H | Allen-Bradley | 1747-M13 | Allen-Bradley | 1772-LG |
Allen-Bradley | 1761-CBL-PM02 | Allen-Bradley | 1756-OB16I | Allen-Bradley | 1783-EMS08T |
Allen-Bradley | 1762-L24BWA | Allen-Bradley | 1756-BA2 | Allen-Bradley | 1783-MS10T |
Allen-Bradley | 1768-L43 | Allen-Bradley | 1756-EN2T | Allen-Bradley | 1784-PCMK |
Allen-Bradley | 1769-ADN | Allen-Bradley | 1756-EN2TR | Allen-Bradley | 1785-L80E |
Allen-Bradley | 1769-BA | Allen-Bradley | 1756-HYD02 | Allen-Bradley | 1785-LT |
Allen-Bradley | 1769-IA16 | Allen-Bradley | 1756-IA16I | Allen-Bradley | 1786-RPFM |
Allen-Bradley | 1769-IQ16 | Allen-Bradley | 1756-IB16D | Allen-Bradley | 1786-TPR |
Allen-Bradley | 1769-L27ERM-QBFC1B | Allen-Bradley | 1756-IR6I | Allen-Bradley | 1788-DNBO |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020