Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / GE FANUC / 6VAF343002B-A2 GE Input module Brand new

6VAF343002B-A2 GE Input module Brand new

The Run/Stop switch is enabled by default; it can be disabled in the PME Hardware Configuration (HWC) settings. The memory protection function of this switch can be disabled separately in HWC. The memory protection functionality is disabled by default.

INQUIRE NOW

Products Name: 6VAF343002B-A2 GE Input module Brand new

PRODUCT DESCRIPTION

Brand:GE

Model number:6VAF343002B-A2

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.27kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

6VAF343002B-A2  GE   Input module Brand new  


image.png

 


 DLAN/DLAN+ (Drives Local Area 
Network) Interface restrictions
PACSystems RX7i CPUs with firmware versions 1.50 or later support 
DLAN Interface, IC697BEM763 modules with firmware versions 3.00 
or later. You must ensure that you are using a valid version of the 
DLAN firmware because the CPU cannot check the DLAN’s firmware 
version. (The module’s firmware version can be found on a label 
attached to the EEPROM.)
If your RX7i application program needs to access the DLAN’s dual port 
memory, use the BUS READ and WRITE functions. When accessing a 
DLAN module, set the Region parameter on the function block to 1. 
(For the DLAN module, region 1 is predefined to be the module's 
entire dual port memory.)
The DLAN is only supported in the main RX7i rack. It is not supported 
in expansion racks.
Note: The DLAN Interface module is a specialty module with limited 
availability. If you have a DLAN system, refer to the 
DLAN/DLAN+ Interface Module User’s Manual, GFK-0729 for 
details.
Genius Bus Controller restrictions The following restrictions apply to GBCs in PACSystems RX7i:
 The minimum CPU sweep time will be gated by the time it takes 
the GBC to refresh its outputs and collect its inputs + 500 
microseconds. To obtain a smaller sweep time, use the SUSIO 
function block or place the GBCs in a scan set that has nondefault characteristics.
 If a %W reference address is used for COMMREQ status or 
return data, it must be in the range %W00001 - %W65536.
 Storing or clearing a hardware configuration containing two GBCs 
attached to the same Genius network may cause a Loss of 
Device fault for one of the GBCs. This is caused by the GBCs 
clearing their SBAs asynchronously. The user can safely ignore 
the Loss of Device fault. 
 

 

image.png

Discrete Input 

Modules(1) IC200MDL140 Input 120 VAC (1 Group of 8) 8 

Points IC200MDL631 Input 125 VDC Pos/Neg Logic 

Isolated 8 Points

IC200MDL141 Input 240 VAC (1 Group of 8) 8 

Points IC200MDL632 Input 125 VDC Pos/Neg Logic 

Isolated 16 Points

IC200MDL143 Input 120 VAC Isolated 8 Points IC200MDL635 Input 48 VDC Pos/Neg Logic (2 

Groups of 8) 16 Points

IC200MDL144 Input 240 VAC Isolated 4 Points IC200MDL636 Input 48 VDC Pos/Neg Logic (4 

Groups of 8) 32 Points

IC200MDL240 Input 120 VAC (2 Groups of 8) 16 

Points IC200MDL640 Input 24 VDC Pos/Neg Logic (2 

Groups of 8) 16 Points

IC200MDL241 Input 240 VAC (2 Groups of 8) 16 

Points IC200MDL643 Input 5/12 VDC Pos/Neg Logic (2 

Groups of 8) 16 Points

IC200MDL243 Input 120 VAC Isolated 16 Points IC200MDL644 Input 5/12 VDC Pos/Neg Logic (4 

Groups of 8) 32 Points

IC200MDL244 Input 240 VAC Isolated 8 Points IC200MDL650 Input 24 VDC Pos/Neg Logic (4 

Groups of 8) 32 Points