ICS T8431 Output Point I/O Module






INQUIRE NOW

Products Name: ICS T8431 Output Point I/O Module

PRODUCT DESCRIPTION

Product Description

ICS Discrete Input Modules are components used in industrial control systems to monitor the status of digital (on/off) signals from field devices such as switches, pushbuttons, sensors, and relays. These modules convert external signals into a format that a PLC or PAC can process, enabling real-time decision-making and control. ICS (Industrial Control Systems) discrete input modules are widely deployed in industries like manufacturing, energy, and infrastructure for their robustness and reliability.


Product Parameters

While specifications vary by model, the following are typical parameters for ICS discrete input modules:

ParameterTypical Value / Range
Number of Inputs8, 16, 32, or 64 points
Input TypeDC, AC, or AC/DC compatible
Input Voltage Range12–24 VDC, 24–48 VAC, 100–240 VAC
Input Current5–15 mA per point
Logic TypePositive or Negative (Sink/Source)
IsolationOpto-isolated, group or channel-wise
Response Time< 10 ms (typical)
LED IndicatorsPer-point status LEDs
Backplane CompatibilityICS PACSystems, GE Fanuc RX3i/90-30
Operating Temperature0°C to +60°C
Humidity5–95% (non-condensing)
CertificationsUL, CE, cUL, ATEX (for certain models)

Product Advantages

  • High-Density Inputs: Many modules offer 32 or 64 input points, saving space and reducing cost per point.

  • Flexible Voltage Support: Compatible with a wide range of input voltages for various field devices.

  • Robust Isolation: Opto-isolation protects the controller from noise, voltage spikes, and ground loops.

  • Diagnostic Capabilities: Many modules include per-point status LEDs and diagnostics for quick troubleshooting.

  • Modular Design: Hot-swappable in some systems, minimizing downtime during maintenance.

  • Long-Term Reliability: Designed for harsh industrial environments with extended temperature and vibration tolerance.

  • Compatibility: Works seamlessly with ICS PACSystems and other major PLC platforms.


Precautions

  • Voltage Matching: Ensure the input voltage range matches the field device to avoid damage or malfunction.

  • Wiring Accuracy: Incorrect wiring (e.g., polarity reversal) may result in permanent damage to the module.

  • Current Limitation: Do not exceed the maximum current rating per input point or per module.

  • Environmental Considerations: Avoid installation in environments with excessive condensation, corrosive gases, or extreme temperatures beyond rated limits.

  • Grounding: Proper grounding is essential to avoid noise interference and ensure accurate signal detection.

  • EMC Compliance: Use shielded cables and proper installation practices to maintain electromagnetic compatibility (EMC).

  • Fusing: Some models may require external fuses for overcurrent protection.


Product Applications

ICS Discrete Input Modules are widely used across industries for real-time digital signal monitoring:

  • Manufacturing Automation: Monitors pushbuttons, selector switches, and emergency stops on production lines.

  • Process Control: Used in chemical and pharmaceutical plants for status feedback from valves, pumps, and alarms.

  • Material Handling: Interfaces with photoelectric sensors, proximity switches, and limit switches in conveyors and automated storage systems.

  • Energy and Utilities: Monitors circuit breakers, relays, and status indicators in power distribution and substation automation.

  • Water Treatment: Tracks float switches, pressure switches, and flow sensors in pumping stations and filtration systems.

  • Building Automation: Integrates with HVAC systems, lighting controls, and security panels for facility management.

  • Transportation: Used in railway signaling, traffic control systems, and baggage handling systems.


Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

FACTORY171CCC96030EPSONSKP326-2
FAGORMCS-20LEquipeATM-407B-1-S-CE
FALCONSG2K-1TEquipeATM-4814
FALK97-0K0473-004EquipeATM-1918
FALKRK2040FZEquipeATM-1710
FALK2090GHB1-KBEquipePRE-300B-L-2-CCD
FERRAZA480R4R-1EricssonELU-D3
ferrocontrolBTR-12EricssonFSU925
FIDIACUR10ESTICENRZ-TU013-S
FieldServerFS-RA-CLX-BAS-406ESTICENRZ-AU30
FIFE CORP534738-001ESTICENRZ-AU40-20
FISHMANLDS9000-3ESTICENRZ-DU20
FLENDERKAF80KESTICENRZ-TU013-S
FLOWSERVE20-755W-120AESTICTNA1-CU20C
FLOWSERVE4MSX7ATESTICENRZ-TU013-OP
FlukePM6306ETELDSB2S154-211E-000H
FlukePM6681Eurotherm955D8R22
FMC3160-100-AEVIEWMT506LV4CN
FORCEPMC422FPEXCAVATORPC200LC-8
FORCECPU-30ZBEFACEPS3710A-T42-1G-NO60


E-mail: alex@fenoux.com

Tel.: +86 13338369201

Skype: +86  13338369201

WhatsApp: +86  13338369201