Schneider TAC Xenta 401B Relay output module
INQUIRE NOW
Products Name: Schneider TAC Xenta 401B Relay output module
PRODUCT DESCRIPTION
The TAC Xenta 401:B is a microprocessor-based controller designed for heating and air handling systems. Unlike the standard 401 model, the 401:B does not support the connection of TAC Xenta 400 I/O modules. Instead, it is optimized to act as a central hub or "Data Manager" that coordinates other LonWorks nodes, manages time schedules, handles alarms, and logs data across a network.
It is programmed using the graphical tool TAC Menta and communicates via the LonTalk TP/FT-10 protocol.
| Feature | Details |
| Supply Voltage | $24\text{ V AC} \pm 20\%, 50/60\text{ Hz}$ or $19-40\text{ V DC}$ |
| Power Consumption | Max $2\text{ W}$ |
| Communication | LonTalk TP/FT-10 (Twisted Pair) |
| I/O Capacity | None (No physical I/O or Xenta 400 I/O module support) |
| Real-Time Clock | Included (72-hour power failure protection) |
| Operating Temp | $0^\circ\text{C}$ to $+50^\circ\text{C}$ ($32^\circ\text{F}$ to $122^\circ\text{F}$) |
| Enclosure Rating | IP 20 |
| Memory | Non-volatile (Flash memory for application program) |
| Dimensions | $77 \times 110 \times 122\text{ mm}$ |
Powerful Logic Engine: Despite having no physical I/O, it has full HVAC functionality (control loops, curves, and logic) to manage complex sequences.
LonMark® Certified: Ensures seamless interoperability with other LonWorks-compliant devices from different manufacturers.
Flexible Data Management: Excellent for handling network variables, centralized scheduling, and trend logging for a whole floor or building.
Hot Swappable: The electronics part can be removed or inserted into the terminal base without disconnecting the power or wiring.
Ease of Programming: Uses the TAC Menta tool, which simplifies the creation of custom control strategies through a functional block diagram interface.
The 401:B is specifically suited for roles where physical wiring isn't required at the controller itself, but logic coordination is:
Zone Management: Managing multiple LonWorks-based room controllers (like Xenta 100 series).
Data Logging Hub: Serving as a central point for collecting and storing history data from various network nodes.
Master Scheduler: Coordinating time-based events (occupancy, holidays) for a large network of decentralized devices.
Gateway to TAC Vista: Acting as the primary communication link between a field network and the TAC Vista BMS workstation.
No I/O Support: Crucial Note: You cannot connect TAC Xenta 400 I/O modules (like 411, 421, etc.) to a 401:B. If physical I/O expansion is needed, you must use the standard TAC Xenta 401 instead.
Wiring: Ensure the LonTalk network is correctly terminated with the proper resistors to avoid communication reflections.
Polarity: While LonTalk TP/FT-10 is generally non-polarized, always double-check the 24V power wiring to prevent damage.
Environment: The unit is designed for cabinet mounting; ensure adequate ventilation and protection from high humidity.

Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
| SCHNEIDER | 2094-BM01-S | SCHNEIDER | 2711-T9C3 |
| SCHNEIDER | 2094-BMP5-S | SCHNEIDER | 3051TG4A2B21AE5M5T1 |
| SCHNEIDER | 2098-DSD-020X | SCHNEIDER | 3180045-01 |
| SCHNEIDER | 2098-DSD-HV030-SE | SCHNEIDER | 31C075-503-4-00 |
| SCHNEIDER | 2098-DSD-HV220-SE | SCHNEIDER | 31C450-503-4-00 |
| SCHNEIDER | 215RIO | SCHNEIDER | 353A4F1CNB4 |
| SCHNEIDER | 22/06-69I/P | SCHNEIDER | 353A4F1NNLNNNA |
| SCHNEIDER | 2200-396-013-AA | SCHNEIDER | 353a4f1nnlnnnax |
| SCHNEIDER | 22F-D013N104 | SCHNEIDER | 353A4FNCNB4 |
| SCHNEIDER | 24031-0-111000000000 | SCHNEIDER | 359651-02 |
| SCHNEIDER | 2706-P44C | SCHNEIDER | 372SPU47401V26 |
| SCHNEIDER | 2711C-T4T | SCHNEIDER | 3AFE68608538 |
| SCHNEIDER | 2711-K10C20 | SCHNEIDER | 3BHB006338R0001 |
| SCHNEIDER | 2711-K10G3 | SCHNEIDER | 3BHB021400R0002 |
| SCHNEIDER | 2711-m3a18l1 | SCHNEIDER | 3BHE014135R0011 |
| SCHNEIDER | 2711-M3A-18L1 | SCHNEIDER | 3BHE026284R0102 |
| SCHNEIDER | 2711PC-RP1 | SCHNEIDER | 3BHT300007R1 |
| SCHNEIDER | 2711P-T12C6D2 | SCHNEIDER | 3BHT300025R1 |
| SCHNEIDER | 2711R-T10T | SCHNEIDER | 3BSC690103R2 |
| SCHNEIDER | 2711-T10C8E | SCHNEIDER | 3BSC760004R1 |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020