Brand: Schneider
Model number:XS630B1MBL2
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
SCHNEIDER XS630B1MBL2 ControlLinks actuator
INQUIRE NOW
Products Name: SCHNEIDER XS630B1MBL2 ControlLinks actuator
PRODUCT DESCRIPTION
Schneider Electric output modules typically fall into two main categories:
Digital Output Modules: These modules provide discrete (on/off) signals. They are used to control devices that only require two states, like turning a light on or off, starting or stopping a motor, or activating a relay. Common types include:
Relay Output Modules: Offer isolated contacts suitable for switching AC or DC loads. They provide good electrical isolation between the control circuit and the load.
Transistor Output Modules (Solid State): Provide fast switching speeds and are suitable for applications requiring frequent switching or higher frequencies. They are typically used for DC loads and are often protected against short circuits, overloads, and reverse polarity.
Analog Output Modules: These modules provide variable signals, typically current (e.g., 0-20mA, 4-20mA) or voltage (e.g., 0-10V, +/-10V). They are used to control devices that require proportional control, such as variable speed drives, proportional valves, or dimmable lights.
While specific specifications vary by module series (e.g., Modicon M340, Modicon X80, EcoStruxure Building Operation), common details include:
Output Channels: Modules come with a varying number of output channels (e.g., 4, 8, 12, 16, 32 outputs).
Output Type:
Digital: Relay (Form A, Form C), Transistor (Source, Sink).
Analog: Current (0-20mA, 4-20mA), Voltage (0-10V, +/-10V).
Output Voltage/Current Rating: Specifies the maximum voltage and current the module can safely switch or provide per channel and for the entire module. For example, a digital output might handle 5A at 250VAC, while an analog output might provide 20mA.
Resolution (for Analog Modules): Typically expressed in bits (e.g., 12-bit, 15-bit, 16-bit), indicating the precision of the analog output signal. Higher bits mean finer control.
Response Time: The time it takes for the output to change state (e.g., 1.2 ms for digital outputs, <= 1 ms for analog conversion).
Insulation Voltage: The electrical isolation between channels, and between channels and the bus/ground, ensuring protection against electrical noise and faults.
Protection Types: Many modules feature built-in protection against:
Short Circuit: Protects the module and connected devices from overcurrents.
Overload: Prevents damage from excessive loads.
Overvoltage: Shields against voltage spikes.
Reverse Polarity: Protects if the power supply is connected incorrectly.
Thermal Overload: Prevents overheating of the module.
Current Consumption: The power drawn by the module itself (e.g., mA at 24V DC).
Load Impedance: The acceptable range of impedance for connected loads.
Mounting: Typically DIN rail mountable for easy integration into control cabinets.
Dimensions and Weight: Varies depending on the number of channels and module type.
Operating and Storage Temperature: Defines the ambient temperature range for reliable operation (e.g., 0 to 60°C for operation, -40 to 85°C for storage).
Relative Humidity: The permissible humidity levels (e.g., 5-95% non-condensing).
IP Degree of Protection: Indicates protection against dust and water ingress (e.g., IP20 for most modules).
Vibration and Shock Resistance: Ensures durability in industrial environments, often conforming to IEC standards.
Certifications: Common certifications include CE, UL, CSA, RCM, EAC, ensuring compliance with international safety and quality standards.
Status LEDs: LEDs (Green/Red) often provide visual feedback on module status (RUN, ERR) and individual channel status.
Fallback Mode: Configurable predefined states for outputs in case of a fault or communication loss, ensuring system safety.
Hot Swapping (for some modules): Allows modules to be replaced without powering down the entire system, minimizing downtime.
Channel Diagnostics: Individual channel diagnostics for easier troubleshooting.
Compatibility: Designed to integrate seamlessly with Schneider Electric PACs (Programmable Automation Controllers) like Modicon M340, M580, and distributed I/O solutions like Modicon STB.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
SCHNEIDER | 2094-BM01-S | SCHNEIDER | 2711-T9C3 |
SCHNEIDER | 2094-BMP5-S | SCHNEIDER | 3051TG4A2B21AE5M5T1 |
SCHNEIDER | 2098-DSD-020X | SCHNEIDER | 3180045-01 |
SCHNEIDER | 2098-DSD-HV030-SE | SCHNEIDER | 31C075-503-4-00 |
SCHNEIDER | 2098-DSD-HV220-SE | SCHNEIDER | 31C450-503-4-00 |
SCHNEIDER | 215RIO | SCHNEIDER | 353A4F1CNB4 |
SCHNEIDER | 22/06-69I/P | SCHNEIDER | 353A4F1NNLNNNA |
SCHNEIDER | 2200-396-013-AA | SCHNEIDER | 353a4f1nnlnnnax |
SCHNEIDER | 22F-D013N104 | SCHNEIDER | 353A4FNCNB4 |
SCHNEIDER | 24031-0-111000000000 | SCHNEIDER | 359651-02 |
SCHNEIDER | 2706-P44C | SCHNEIDER | 372SPU47401V26 |
SCHNEIDER | 2711C-T4T | SCHNEIDER | 3AFE68608538 |
SCHNEIDER | 2711-K10C20 | SCHNEIDER | 3BHB006338R0001 |
SCHNEIDER | 2711-K10G3 | SCHNEIDER | 3BHB021400R0002 |
SCHNEIDER | 2711-m3a18l1 | SCHNEIDER | 3BHE014135R0011 |
SCHNEIDER | 2711-M3A-18L1 | SCHNEIDER | 3BHE026284R0102 |
SCHNEIDER | 2711PC-RP1 | SCHNEIDER | 3BHT300007R1 |
SCHNEIDER | 2711P-T12C6D2 | SCHNEIDER | 3BHT300025R1 |
SCHNEIDER | 2711R-T10T | SCHNEIDER | 3BSC690103R2 |
SCHNEIDER | 2711-T10C8E | SCHNEIDER | 3BSC760004R1 |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020